C-Tec Standard 2 Zone Conventional Fire Alarm Panel CFP702-4
Description
The C-Tec Standard 2 Zone Conventional Fire Alarm Panel CFP702-4 is supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters and relay expansion boards also available.
More Information:
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
 - Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
 - Manufactured by C-TEC in the UK.
 - Two detector zone circuits.
 - Four conventional sounder circuits*
 - Integral 1.5A EN54-4/A2 compliant switch mode PSU.
 - Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
 - Two on-board relays (Fire and Fault).
 - Two open-collector outputs (Remote and Reset).
 - ‘Class change’ and alert inputs.
 - Installer-friendly design.
 - Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
 - Low 25mA quiescent current.
 - Multiple indicators.
 - System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system) and optional CFP relay boards.
 - Space for two x 12V 3.3Ah VRLA batteries.
 - Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices.
 
| Approvals/certifications | 
 Certifed to EN54 Parts 2 & 4 by the LPCB., Certified to EN54-13 by Kiwa Telefication.  | 
|---|---|
| Mains supply | |
| Mains rated current | |
| Internal power supply | |
| Total output current limited to | |
| Quiescent current | 
 25mA (mains failed, internal sounder active, PSU & gen fault LED lit)  | 
| Max battery size and type | 
 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah.  | 
| No. of detector zone circuits | |
| Call point resistor value | |
| Max. devices per detector zone | |
| No. of conventional sounder circuits | |
| EOL resistor value | |
| Alarm voltage | |
| Max. sounder output current | |
| Auxiliary relays | |
| Open collector outputs | |
| Other outputs | 
 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed).  | 
| Auxiliary inputs | |
| Engineer (AL3) functions | |
| Expansion connections | |
| Product dimensions (mm) | |
| Construction & finish | |
| IP Rating | |
| Weight | |
| Operating conditions/temperature | 
The C-Tec Standard 2 Zone Conventional Fire Alarm Panel CFP702-4 is supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters and relay expansion boards also available.
More Information:
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
 - Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
 - Manufactured by C-TEC in the UK.
 - Two detector zone circuits.
 - Four conventional sounder circuits*
 - Integral 1.5A EN54-4/A2 compliant switch mode PSU.
 - Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
 - Two on-board relays (Fire and Fault).
 - Two open-collector outputs (Remote and Reset).
 - ‘Class change’ and alert inputs.
 - Installer-friendly design.
 - Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
 - Low 25mA quiescent current.
 - Multiple indicators.
 - System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system) and optional CFP relay boards.
 - Space for two x 12V 3.3Ah VRLA batteries.
 - Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices.
 
| Approvals/certifications | 
 Certifed to EN54 Parts 2 & 4 by the LPCB., Certified to EN54-13 by Kiwa Telefication.  | 
|---|---|
| Mains supply | |
| Mains rated current | |
| Internal power supply | |
| Total output current limited to | |
| Quiescent current | 
 25mA (mains failed, internal sounder active, PSU & gen fault LED lit)  | 
| Max battery size and type | 
 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah.  | 
| No. of detector zone circuits | |
| Call point resistor value | |
| Max. devices per detector zone | |
| No. of conventional sounder circuits | |
| EOL resistor value | |
| Alarm voltage | |
| Max. sounder output current | |
| Auxiliary relays | |
| Open collector outputs | |
| Other outputs | 
 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed).  | 
| Auxiliary inputs | |
| Engineer (AL3) functions | |
| Expansion connections | |
| Product dimensions (mm) | |
| Construction & finish | |
| IP Rating | |
| Weight | |
| Operating conditions/temperature | 