C-tec CFP Standard 8 Zone Conventional Fire Alarm Panel CFP708-4

C-TecSKU: CFP708-4

Price:
Sale price£213.63

Description

C-tec CFP Standard 8 Zone Conventional Fire Alarm Panel CFP708-4

Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.

Optional repeaters and relay expansion boards also available.

 

        

  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
  • Manufactured by C-TEC in the UK.
  • Eight detector zone circuits.
  • Four conventional sounder circuits.
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  • Two on-board relays (Fire and Fault).
  • Two open-collector outputs (Remote and Reset).
  • ‘Class change’ and alert inputs.
  • Installer-friendly design.
  • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
  • Low 25mA quiescent current.
  • Multiple indicators.
  • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
  • Space for two x 12V 3.3Ah VRLA batteries.
  • Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices.
Technical Specifications
Approvals/certifications

,

Mains supply

Mains rated current

Internal power supply

Total output current limited to

Quiescent current

Max battery size and type

No. of detector zone circuits

Call point resistor value

Max. devices per detector zone

No. of conventional sounder circuits

EOL resistor value

Alarm voltage

Max. sounder output current

Auxiliary relays

Open collector outputs

Other outputs

Auxiliary inputs

Engineer (AL3) functions

Expansion connections

Product dimensions (mm)

Construction & finish

IP Rating

Weight

Operating conditions/temperature